DrehtagWerkTools for the shooting day
Calculators · Lighting

Power load on a circuit

Enter your fixtures and see how much current they draw and whether the circuit can carry it.

Circuit


Loads

W
W
W
W
Use the power draw from the data sheet, not the light output. Include other equipment on the same circuit.
Result
Current draw
Total power
Circuit carries
Load

Diagram

Load on the circuit with markers at 80 percent (continuous load) and 100 percent (breaker rating).

How it is calculated

current in A = total power in W ÷ voltage in V

A circuit protected at 16 A carries 3680 W at 230 V on paper. For continuous loads over hours, the usual practice is to plan for no more than 80 percent of that. The calculator flags anything above as tight.

Safety note

This calculator does not replace an inspection by a qualified electrician. Several sockets often share one circuit, cable reels must be fully unwound under load, and inrush currents, reactive power and the condition of the installation are not taken into account here.

Advertisement · placeholder for an ad slot